LB recommends a service interval of 4,8 and 12 years after purchase of all tactical altimeters.
Reference instrument: Omega HHP-360A (or other calibrated pressure device with a millibar readout)

Checklist
1. Turn on altimeter and check start up millibar pressure matches reference instrument
2. Place reference instrument and altimeter(s) in a vacuum chamber
3. Watch that they are both showing the same readout throughout the simulated jump

If there is no discrepancy compared to the manual there is no need to return the unit for service

Maintenance includes: Diagnostics, battery replacement, battery cover inspection (replacement if necessary), replacement of worn out sealings, applicable software updates if version number and PCB version allow, waterproof testing, final functional testing (flight performance in test chamber)

Service on units from before 2021 - the model without the rails - comes with an extra charge. Select the correct model in the drop-down below.

In Europe and Asia ship the unit to:

LARSEN & BRUSGAARD ApS
Ledreborg Allé 28
4000 Roskilde
Denmark

Outside of Europe and Asia ship the unit to:

LB ALTIMETERS US
8325 Broadway St.
Suite 202 #94
Pearland, TX 77581
USA

Please add a note with known issues or technical problems.

Return shipment is not included. Remember to add return shipment to your order (see below under the features tab)

For more information for tactical service email serviceus@lbaltimeters.com.

LB recommends a service interval of 4,8 and 12 years after purchase of all tactical altimeters. Reference instrument: Omega HHP-360A (or other calibrated pressure device with a millibar readout)

Checklist:

  • Turn on altimeter and check start up millibar pressure matches reference instrument
  • Place reference instrument and altimeter(s) in a vacuum chamber
  • Watch that they are both showing the same readout throughout the simulated jump

If there is no discrepancy compared to the manual there is no need to return the unit for service